System chosen
Due to the difficulties associated with
providing the required drainage for a cavity-drain membrane system, a
cement based waterproofing system was chosen. Vandex BB75 was applied to the walls, Vandex BB75e to the floor-wall juncture and Vandex Uni-mortar 1 to the floor slab.
To help control the condensation problem within the vault, an insulation based plastering system was used comprising of thermal boards and studded walls packed with Rockwool insulation. A plaster finish and new skirting boards completed the installation. |